can water line and electrical in same trench

can water line and electrical in same trench

Installation Requirements for Underground Conduit Systemstrench, prior to installation of any conduit, with adequate length at each end for connections by the Cooperative. 9 When electric facilities are installed in the same trench as communiion facilities, a No. 6 AWG copper bonding conductor, readily accessible atUnderground Water Main & Electrical Lines in the Same …First time for everything it seems. During an inspection of the underground water mains for a new facility, our inspector…


trench, prior to installation of any conduit, with adequate length at each end for connections by the Cooperative. 9 When electric facilities are installed in the same trench as communiion facilities, a No. 6 AWG copper bonding conductor, readily accessible at

Underground Water Main & Electrical Lines in the Same …

First time for everything it seems. During an inspection of the underground water mains for a new facility, our inspector observed the incoming electrical service lines loed in the same trench and directly above the incoming water main for the fire sprinkler system. I Puhui Pipe manufacturer in China

The minimum trench depth for a gas line is 12", and the same is true for water lines where freezing is not a concern. The electrical, though, must be deeper (either 18" or 24" deep), so that sets your trench …

12/3/2010· Electrical came off a different corner but gas, water, and telephone all went in the same trench. We did have to keep 24 inches between the electrical and gas where the trenches crossed but that was 400amp service to the house.

Can water and sewer pipes be in the same trench? Yes, but with certain requirements as the water piping has to be higher then the sewer line among other code items

7/6/2014· Ah. Legitimate with a 12" separation. Meaning that your trench is over 2 1/2 feet deep. Seeing as a water line can be buried at a much less depth than that, I think 1'' is ok, I don''t see value in the effort. But that is me.

27/6/2012· • Electrical lines can be placed in the same trench as the water line with the electrical line placed above the water line with a twelve (12) inch earth separation. More options K

9/7/2010· They dug a trench across the road, laid in a 2" plastic duct and fed their cable through it. Then along came the water. To save them digging up the road, they pushed their pipe through the same duct. Then along came BT, and yes they used the same duct.

24/9/2007· I am preparing to run electricity, water, and phone lines from my house to my new pole barn. Distance is about 210 feet. I have asked a nuer of people and get different answers. I plan on renting a ditch witch and dig a trench for the lines. My question is how Puhui Pipe manufacturer in China

9/7/2010· They dug a trench across the road, laid in a 2" plastic duct and fed their cable through it. Then along came the water. To save them digging up the road, they pushed their pipe through the same duct. Then along came BT, and yes they used the same duct.

A goose neck pipe can not be bought. It is just a straight piece of electrical conduit when it starts. No. The fittings are not water-tight and the pipe will corrode. Use copper, PVC Puhui Pipe manufacturer in China

21/9/· Just seeing how you guys feel about running Underground gas in same trench as electric. is it 12" minimum separation in all states? Just seeing how you guys feel about running Underground gas in same trench as electric. is it 12" minimum separation in all states?

First time for everything it seems. During an inspection of the underground water mains for a new facility, our inspector observed the incoming electrical service lines loed in the same trench and directly above the incoming water main for the fire sprinkler system. I Puhui Pipe manufacturer in China

4/12/2007· Does anyone know if I can run MDPE blue water pipe on top of the electricity cable, in the same trench? I just had my electrician running a SWA cable into the shed, through the garden (about 10 m length), and the trench has not been completely filled yet (I''ll still have to do that myself), so I''m thinking of taking advanPE100 ISO9001e and use the same trench for a water pipe too.

24/3/2011· I am currently working for a hdpe pipes and we are converting a dry cleaning shop into a restaurant. My question is can I put my conduit in the same trench as a pluing drain? Thanks for the quick replies. I''ll definitely check with ahj just to make sure. I didn''t think

24/9/2007· I am preparing to run electricity, water, and phone lines from my house to my new pole barn. Distance is about 210 feet. I have asked a nuer of people and get different answers. I plan on renting a ditch witch and dig a trench for the lines. My question is how Puhui Pipe manufacturer in China

Pipeline Separation Design & Installation Guidance

Table 3: Estimates of horizontal pipe separation vs. critical trench depth for water line buried at 3.5 feet Puhui Pipe manufacturer in China television and electrical power. In many water-limited areas, piped irrigation water lines are common, with reclaimed water being added to the collection of Puhui Pipe manufacturer in China

28/1/2010· I helped put in 5, coax, and power lines from a friend''s house to his shop that was just over 100ft of trench. We put the power lines in a conduit, water supply, then 5 and coax in a separate conduit. We put them into the same trench and buried them all

You can offset the electric to one side of the trench and the communiions to the other side of the trench for more separation distance at the same depths. I''d strongly recommend two layers of "warning tape," one just below the surface, and one below the communiions conduit and above the electrical wire, so it''s clear that there is an electric wire as well as the communiions conduit.

21/9/· Just seeing how you guys feel about running Underground gas in same trench as electric. is it 12" minimum separation in all states? Just seeing how you guys feel about running Underground gas in same trench as electric. is it 12" minimum separation in all states?

15/5/2010· minium seperation between low volPE100 ISO9001e (240V- 415) electrical service and water service not greater than DN65* is 100mm. so make your trench atleast 300mm wide. if you are running the conduit yourself makesure you replace the dirt with dolimite sand for the first 300mm and then place marker tapeto comply with clause 3.11.4.5 and 3.9.8.4

15/5/2010· minium seperation between low volPE100 ISO9001e (240V- 415) electrical service and water service not greater than DN65* is 100mm. so make your trench atleast 300mm wide. if you are running the conduit yourself makesure you replace the dirt with dolimite sand for the first 300mm and then place marker tapeto comply with clause 3.11.4.5 and 3.9.8.4

Table 3: Estimates of horizontal pipe separation vs. critical trench depth for water line buried at 3.5 feet Puhui Pipe manufacturer in China television and electrical power. In many water-limited areas, piped irrigation water lines are common, with reclaimed water being added to the collection of Puhui Pipe manufacturer in China

23/3/2008· Yep, that is why the NESC requires separation from the gas line of one foot. I don''t know about the water and sewer (I don''t have a copy of the NESC with me) but the power and communiions can be random lay (in the same trench without any intentional.

28/1/2010· I helped put in 5, coax, and power lines from a friend''s house to his shop that was just over 100ft of trench. We put the power lines in a conduit, water supply, then 5 and coax in a separate conduit. We put them into the same trench and buried them all

Trench inspections take 48 hours to organise and the inspector must approve the trench before it is filled in. We recommend work starts at the boundary, working towards your property. If the leak is then discovered just past the boundary, work can stop (saving additional cost) while we investigate.